lape
  LAPE e-log  ELOG logo
Message ID: 117     Entry time: Thu Oct 24 19:23:02 2013
Author: Valdir Salustino 
Type: Routine 
Category: Espectroscopia 
Subject: Vibration runs log 

24/10

First Run of noise sample.

File exported from power Spectrum to excell file (File Name : noise_run0)

Info:

Air flow off.

AC - off.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 

Secound Run of noise sample.

File exported from power Spectrum to excell file (File Name : noise_run1)

Info:

Air flow off.

AC - ON.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 

First Run with air flow 

File exported from power Spectrum to excell file (File Name : run0_press_bar1)

Info:

Air flow pressure = 1 bar.

AC - ON.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 

Second Run with air flow 

File exported from power Spectrum to excell file (File Name : run0_press_bar1point5)

Info:

Air flow pressure = 1.5 bar.

AC - ON.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 

29/10

Run 3)

 File exported to .txt File Name : run3_press_2bar

Info:

Air flow pressure = 2.0 bar.

AC - ON.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 
 
Run 4)
 File exported to .txt File Name : run4_noise_with_silicon_slab

Info:

Air flow pressure = 0.0 bar.

AC - ON.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 
Run 5)
 File exported to .txt File Name : run5_press_1bar_with_silicon_slab

Info:

Air flow pressure = 1.0 bar.

AC - ON.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 

Run 6)
 File exported to .txt File Name : run6_press_1p5bar_with_silicon_slab

Info:

Air flow pressure = 1.5 bar.

AC - ON.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 

Run 7)
 File exported to .txt File Name : run7_press_2bar_with_silicon_slab

Info:

Air flow pressure = 2 bar.

AC - ON.

Number of averages = 100

RMS averaging

Samples do Read 100k

Rate 100k

Weighting Mode: Linear

 
 
 
ELOG V2.9.2-2455